Tuesday, February 25, 2014

barometric-damper

Barometric damper


Hi everybody, All what I want to know is: what is the purpose of having a Barometric Damper on the flute of a furnace? Do all oil furnaces need Barometric Damper? If no, what type of oil furnace must have the damper installed? Your explaination will be highly appreciated. Thank you very much beforehand. Tuan Le tuanle: Here is a quote from another site that explains it better than I can: A TEE section is inserted into the stove pipe. In the side of the TEE, a weighted flap is installed. Whenever the chimney suction is greater than the stove or furnace needs, the flap rotates open and lets room air into the chimney, thereby spoiling the draft. The benefit is that the stove or furnace will work more efficiently with a steady draft as opposed to constant changes in the chimney suction. For instance, a coal or wood stove may burn more steadily and for a longer period of time. An oil furnace will also be more efficient and less heat will be sucked up the flue when the unit is on AND off. Hi Greh, I am happy with your answer. Just one more question: Do all oil furnaces need Barometric Damper? Thank you. No, Just the Oil furances that needs them. The older style gas furnaces, (Not 80% and 90% eff) and gas water heater use a vent hood, or a draft diveriter. They are just on top of the unit or just off the side of the heat exchanger. It act the same as the ones used on oil. Oil furance is under a slight pressure vs gas burning units. and that's why the damper is away from the oil unit itself. Nat gas is not under pressure in the burner area, and just works it's way out to the top or side, and is mixed in the vent hood/divitor. As the chimmey gets warm, it will Pull harder. so as it pulls, it will pull room air into the hood, and mixed in with the exhaust from the heat exchanger. As the boys have told you, it all depends on draft. Most manufacturers instructions ask for .02in. w.c. draft over the fire. What that means is that if you have a U shaped glass tube partially filled with water and you connected a hose to one upright part of the U and put that hose inside the furnace, The draft inside the furnace should make the water rise up in that side and the difference between one side of the U and the other should be .02 in. As you can see it is a small amount. What should be at the breech (where the smoke pipe connects) is about -.04 in. w.c. Most chimneys make more draft than that and the draft would pull the heat through the furnace way too fast. Faster throughput means hotter temps going up chimney and that tends to increase the draft. Enter the draft regulator. The damper is balanced and adjustable. It should be closed when the unit is off and there isn't much draft in the chimney. Then as draft increases due to heating of the chimney, the damper opens in response to the higher draft and lets cool room air into the chimney. That tends to reduce draft and the damper will close slightly. It should be fluctuating most of the time. If you have minimal draft, it doesn't pay to have a regulator at all and it can be eliminated.








Related Posts:




  • Buderus logamatic 2107 vs taco pc700

    Buderus Logamatic 2107 vs Taco PC-700We’ve decided to replace the 45-year old heating system in our house (oil, indirect water heater, 4-zones, all baseboards, beacon/morris kickspace in kitchen t...


  • Central air wiring

    Central Air WiringOK here's the deal, My brother in law messed with the wires going to the central air unit. There are two sets of wires, one from the thermostat and one to the condensor. Which wi...


  • Diy install aprilaire 500 humidifier couple questions

    DIY install Aprilaire 500 humidifier? Couple questions...I've contemplated putting in a whole-house humidifier a couple times over the past few years, and I'm now fearing the coming dry winter air...


  • 3200 for new air handler 13 seer 25 ton installed too much

    $3200 for new air handler, 13 seer 2.5 ton installed --too much?Hi, I have a dual unit hvac system and the existing 2 ton York F2RP024H06B air handler is creating a ton of condensation, so much so...


  • 4000 sqft home 2 furances required

    4000 sqft Home, 2 furances required?We are in the planning stages of building a two story home with a walkout basement (so really 3), the total sq ft of all 3 floors is around 4000. The back of th...